Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Journal of Breast Cancer ; : 25-34, 2023.
Article in English | WPRIM | ID: wpr-967067

ABSTRACT

Purpose@#Implant-based breast reconstruction is the most common reconstruction method used after mastectomy in breast cancer patients. Many studies have compared the smooth round implants and textured anatomical implants. This study aimed to compare the complications, including capsular contracture, between these two implants used in direct-toimplant (DTI) breast reconstruction. @*Methods@#This retrospective chart review was performed using a prospectively maintained database from a single center. We identified patients who underwent mastectomy with DTI single-stage breast reconstruction at our hospital between August 2011 and June 2021. The overall complications, including capsular contracture, postoperative infection, seroma, hematoma, implant rupture, implant exposure, rippling, implant malposition, and nipple necrosis, were analyzed. @*Results@#In total, 340 breasts of 323 patients were reconstructed by the DTI approach using either textured anatomical (n = 203) or smooth round (n = 137) implants. The incidence of overall complications and capsular contracture was significantly lower with smooth round implants than with textured anatomical implants. Multivariate analysis showed that smooth round implants were associated with a reduced risk of overall complications (odds ratio [OR], 0.465; 95% confidence interval [CI], 0.265–0.813) and capsular contracture (OR, 0.475; 95% CI, 0.235–0.962). Particularly, smooth round implants were associated with a decreased risk of overall complications in patients not receiving adjuvant chemotherapy and a decreased risk of capsular contracture in patients with body mass index < 25 kg/m2 and in those not receiving adjuvant radiotherapy. @*Conclusion@#Smooth round implants demonstrated a decreased risk of overall complications and capsular contracture when compared with textured anatomical implants. These results may be utilized in counseling patients regarding the advantages and disadvantages of smooth round implants in DTI breast reconstruction.

2.
Archives of Craniofacial Surgery ; : 52-58, 2023.
Article in English | WPRIM | ID: wpr-999507

ABSTRACT

Background@#Complex orbital fractures are impure orbital fractures because they involve the orbital walls and mid-facial bones. The author reported an orbital wall restoration technique in which the primary orbital wall fragments were restored to their prior position in complex orbital fractures in 2020. As a follow-up to a previous preliminary study, this study retrospectively reviewed the surgical results of complex orbital wall fractures over a 4-year period and compared the surgical outcomes by dividing them into groups with and without balloon restoration. @*Methods@#Data of 939 patients with facial bone fractures between August 2018 and August 2022 were reviewed. Of these, 154 had complex orbital fractures. Among them, 44 and 110 underwent reduction with and without the balloon technique respectively. Pre- and postoperative Naugle exophthalmometer (Good-Lite Co.) scales were evaluated. The orbital volume and orbital volume ratio were calculated from preoperative and 6 months postoperative computed tomography images. @*Results@#Among 154 patients with complex orbital fractures, 44 patients underwent restoration with the balloon technique, and 110 patients underwent restoration without it. The Naugle scale did not differ significantly between the two groups, but the orbital volume ratio significantly decreased by 3.32% and 2.39% in groups with and without the balloon technique and the difference in OVR was significantly greater in patients in the balloon restoration group compared with the control group. Postoperative balloon rupture occurred in six out of 44 cases (13.64%). None of the six patients with balloon rupture showed significant enophthalmos at 6 months of follow-up. @*Conclusion@#The balloon rupture rate was 13.64% (6/44 cases) with marginal screw fixation, blunt screws, and extra protection with a resorbable foam dressing. Furthermore, we restored the orbital wall with primary orbital fragments using balloon support in complex orbital wall fractures.

3.
Archives of Craniofacial Surgery ; : 309-314, 2020.
Article in English | WPRIM | ID: wpr-830655

ABSTRACT

Reconstructions of extensive composite scalp and cranial defects are challenging due to high incidence of postoperative infection and reconstruction failure. In such cases, cranial reconstruction and vascularized soft tissue coverage are required. However, optimal reconstruction timing and material for cranioplasty are not yet determined. Herein, we present a large skull defect with a chronically infected wound that was not improved by repeated debridement and antibiotic treatment for 3 months. It was successfully treated with anterolateral thigh (ALT) free flap transfer for wound salvage and delayed cranioplasty with a patient-specific polyetheretherketone implant. To reduce infection risk, we performed the cranioplasty 1 year after the infection had resolved. In the meantime, depression of ALT flap at the skull defect site was observed, and the midline shift to the contralateral side was reported in a brain computed tomography (CT) scan, but no evidence of neurologic deterioration was found. After the surgery, sufficient cerebral expansion without noticeable dead-space was confirmed in a follow-up CT scan, and there was no complication over the 1-year follow-up period.

4.
Journal of the Korean Society for Surgery of the Hand ; : 238-242, 2016.
Article in English | WPRIM | ID: wpr-109355

ABSTRACT

Nodular type malignant melanoma is uncommon in fingers. In previous publications, treatment, diagnosis and case reports of subungal melanoma is often, however fingertip lesion was not focused. A 64-year-old woman who had a non-healing red and dark colored nodular mass with ulceration over the finger tip in the right thumb visited our clinics. Biopsy results was malignant melanoma then we performed amputation surgery of distal phalanx. Lymph node biopsy and resection margin was negative for melanoma. Chemotherapy was administered immediately. After 5 months, pulmonary nodular lesion was found and diagnosed as metastatic malignant melanoma by the wedge resection surgery. The patient is treated for additional chemotherapy consistently and disease free for 2 years. Nodular type melanoma of the finger is uncommon and it could be presented as ulceration and amelanotic nodular mass. Therefore we recommend biopsy to diagnose correctly if there are chronic non healing lesions on the fingers.


Subject(s)
Female , Humans , Middle Aged , Amputation, Surgical , Biopsy , Diagnosis , Drug Therapy , Fingers , Lymph Nodes , Melanoma , Thumb , Ulcer
5.
Archives of Plastic Surgery ; : 40-45, 2016.
Article in English | WPRIM | ID: wpr-31012

ABSTRACT

BACKGROUND: Bioabsorbable plates and screws are commonly used to reduce maxillofacial bones, particularly in pediatric patients because they degrade completely without complications after bone healing. In this study, we encountered eight cases of a delayed foreign body reaction after surgical fixation with bioabsorbable plates and screws. METHODS: A total of 234 patients with a maxillofacial fracture underwent surgical treatment from March 2006 to October 2013, in which rigid fixation was achieved with the Inion CPS (Inion, Tampere, Finland) plating system in 173 patients and Rapidsorb (Synthes, West Chester, PA, USA) in 61 patients. Their mean age was 35.2 years (range, 15-84 years). Most patients were stabilized with two- or three-point fixation at the frontozygomatic suture, infraorbital rim, and anterior wall of the maxilla. RESULTS: Complications occurred in eight (3.4%) of 234 patients, including palpable, fixed masses in six patients and focal swelling in two patients. The period from surgical fixation to the onset of symptoms was 9-23 months. Six patients with a mass underwent secondary surgery for mass removal. The masses contained fibrous tissue with a yellow, grainy, cloudy fluid and remnants of an incompletely degraded bioabsorbable plate and screws. Their histological findings demonstrated a foreign body reaction. CONCLUSIONS: Inadequate degradation of bioabsorbable plates caused a delayed inflammatory foreign body reaction requiring secondary surgery. Therefore, it is prudent to consider the possibility of delayed complications when using bioabsorbable plates and surgeons must conduct longer and closer follow-up observations.


Subject(s)
Humans , Absorbable Implants , Follow-Up Studies , Foreign Bodies , Foreign-Body Reaction , Maxilla , Maxillofacial Injuries , Sutures
6.
The Journal of the Korean Orthopaedic Association ; : 599-606, 1995.
Article in Korean | WPRIM | ID: wpr-769679

ABSTRACT

A most common site for the isthmic spondylolisthesis is at fifth lumbar vertebra(L5) and far less at fourth(L4). The pathogenic lesion in the pars interarticularis is essentially the same in LA and L5 isthmic spondylolisthesis, but the clinical characteristics may differ each other according to their anatomical and biomechanical differences. A retrospective review of 24 patients of LA(study group) and 27 patients of L5(control group) isthmic spondylolisthesis was undertaken for their medical records and radiographs to compare the clinical characteristics in each groups. Included in each groups were all patients who were surgically treated during the same period and followed for more than two years after surgery. In the study group, 18 of 24 patients were females having an average age of 42.5 years(ranging 34-65), while in the control group, 17 of 27 patients were males having an average age of 38,1 years (ranging 13-59). The symptoms were severe leg pain in most of the study group, but in the control group, the leg pain and back pain were equally complained. The degrees of slip were similar in two groups, but a narrowing of dise space at slip segment was more prominent in study group. The lateral radiographs taken in flexion and extension revealed more changes of slip in study group (4.7mm in study group vs 2.8mm in control group in averages), and more angular motion at slip segment in study group unless the dise space is not severely narrowed. A spinal stenosis in CT findings was disclosed in almost all patients of study group and in 18 patients of control group. The sizes of L5 transeverse process were bigger than twice as those of L4 in 17(70.8%) patients including 9(37.5%) sacralizations of L5 in suty group, while in control group they were only 8(29.6%) patients with no sacralization. The heights of intercreastal line revealed no difference in two groups. The surgical procedures in study group were fusion only in two and decompression with fusion in 22(91.7%) patients and those in control group were fusion only in 11 and decompression with fusion in 16(59.3%) paticnts. The satisfactory results of treatment were in 21(87.5%) patients of study group and 25(92.6%) patients of control group without significant difference between two groups. In conclusion, the L4 spondylolytic spondylolisthesis compared to L5 lesion was more unstable and developed spinal stenosis more often. The surgical treatment and decompression procedure were also more needed in L4 lesions particularly in agend women.


Subject(s)
Female , Humans , Male , Back Pain , Decompression , Leg , Medical Records , Retrospective Studies , Spinal Stenosis , Spondylolisthesis
SELECTION OF CITATIONS
SEARCH DETAIL